Connector | Fiber Channel |
| |
MPO Female Connectors | 8 Fibers |
Note: Female connector need to connect with male connector type. |
Connector | Reference | Housing Details |
MPO Single Mode | IEC 61754-7 | SM APC: Green connectors+black boot (Standard Loss MPO) SM APC: Yellow connectors+black boot (Super low loss MPO) |
MPO Multimode | IEC 61754-7 | OM1&OM2 PC: Beige connectors+black boot (Standard Loss MPO) OM3&OM4 PC: Aqua connectors+black boot (Standard&Super low
loss MPO) OM3&OM4 PC: Heather Violet connectors+black boot (Standard loss
MPO) |
· Meets IEC Standard IEC-61754-7; IEC61755, Telcordia GR-1435-CORE,
JIS C5982; TIA-604-5(FOCIS5) compliant
· Structured cabling per TIA-568-C
· 10G Fiber Channel Compliant
· 40G and 100G IEEE 802.3
Other connectors’ Industrial Standard:
SC: TIA/EIA, FOCIS3, GR-326.NTT-SC IEC61754-4 and JIS C5973.
LC: TIA/EIA, FOCIS10, GR-326 EIA/TIA-604-10, IEC61754-20 and JIS
C5973.
FC: EIA /TIA-604-04, FOCIS4, NTT-FC, GR-326. IEC61754-13 and JIS
C5973
ST: TIA/EIA, FOCIS2, GR-326. IEC61754-2 and JIS C5973 Etc.
E2000: IEC61754-15
Available for
G657A1 MPO-LC, MPO-SC,MPO-FC,MPO-SC,MPO-ST,MPO-E2000
G657A2/B2 MPO-LC, MPO-SC,MPO-FC,MPO-SC,MPO-ST,MPO-E2000
G657B3 MPO-LC, MPO-SC,MPO-FC,MPO-SC,MPO-ST,MPO-E2000
OM1 62.5/125 MPO-LC, MPO-SC,MPO-FC,MPO-SC,MPO-ST,MPO-E2000
OM2 50/125 MPO-LC, MPO-SC,MPO-FC,MPO-SC,MPO-ST,MPO-E2000
OM3 50/125 MPO-LC, MPO-SC,MPO-FC,MPO-SC,MPO-ST,MPO-E2000
OM4 50/125 MPO-LC, MPO-SC,MPO-FC,MPO-SC,MPO-ST,MPO-E2000
OM5 50/125 MPO-LC, MPO-SC,MPO-FC,MPO-SC,MPO-ST,MPO-E2000
MPO End-Face 3D Interference Index
Item (IEC-61300-3-30) | Minimum | Maximum |
Radius of curvature (mm) | ROC-X(ABS) | 2000 | |
ROC-Y(ABS) | 50mm | |
Angle | Angle-X | -0.2° | -0.2° |
Angle-Y | APC | 7.85° | 8.15° |
PC | -0.2° | -0.2° |
Fiber height (nm) | 1000nm | 3500nm |
Max.DH.All Fiber: | -300nm | 300nm |
DH.Adj: | -300nm | 300nm |
DH.Ave Fiber: | -300nm | 300nm |
Core Dip: | SM | N/A | N/A |
MM | -200nm | 300nm |
LC End-Face Geometry 3D Interference Index
Items | Connector | PC End-face | APC End-face |
Radius of Curvature | SC/FC/ST | 10~25 mm | 5~12 mm |
LC/MU | 7~25 mm | 5~15 mm |
Apex Offset | ≤50 um |
Fiber Spherical Height | +/- 100 nm |
Angular Offset | ------ | 8°± 0.5° |
LC End-face Quality (SM)
Zone | Range (μm) | Scratches | Defects | Reference |
A: Core | 0 to 25 | None | None | IEC 61300-3-35:2015 |
B: Cladding | 25 to 115 | None | None |
C: Adhesive | 115 to 135 | None | None |
D: Contact | 135 to 250 | None | None |
E: Rest of ferrule | None | None |
LC End-face Quality (MM)
Zone | Range (μm) | Scratches | Defects | Reference |
A: Core | 0 to 65 | None | None | IEC 61300-3-35:2015 |
B: Cladding | 65 to 115 | None | None |
C: Adhesive | 115 to 135 | None | None |
D: Contact | 135 to 250 | None | None |
E: Rest of ferrule | None | None |
Cable Drawing